ConFirm® 10 In-Office Biological Monitoring System (Crosstex)
- In-office biological monitioring system provides final results in just 10 hours
- Simply process test indicator vial in a normal steam sterilization cycle, remove, crush ampoule and place in incubator along with an unprocessed control vial for required 10 hour incubation
- Media in test vial will turn yellow if any spores remain alive, thus signifying a failed test; control vial media
- If test fails, immediately retest to determine if sterilizer is not functioning properly or it was human error (most common reason for test failure)
- If second test fails, remove sterilizer from service immediately and contact your local equipment service provider
- In-office biological monitioring system provides final results in just 10 hours
- Simply process test indicator vial in a normal steam sterilization cycle, remove, crush ampoule and place in incubator along with an unprocessed control vial for required 10 hour incubation
- Media in test vial will turn yellow if any spores remain alive, thus signifying a failed test; control vial media
- If test fails, immediately retest to determine if sterilizer is not functioning properly or it was human error (most common reason for test failure)
- If second test fails, remove sterilizer from service immediately and contact your local equipment service provider
Delivery
All orders shipped with UPS Express.
Always free shipping for orders over US $250.
All orders are shipped with a UPS tracking number.
Returns
Items returned within 14 days of their original shipment date in same as new condition will be eligible for a full refund or store credit.
Refunds will be charged back to the original form of payment used for purchase.
Customer is responsible for shipping charges when making returns and shipping/handling fees of original purchase is non-refundable.
All sale items are final purchases.
Help
Give us a shout if you have any other questions and/or concerns.
Email: contact@domain.com
Phone: +1 (23) 456 789
MPN
c10bi25_group
- In-office biological monitioring system provides final results in just 10 hours
- Simply process test indicator vial in a normal steam sterilization cycle, remove, crush ampoule and place in incubator along with an unprocessed control vial for required 10 hour incubation
- Media in test vial will turn yellow if any spores remain alive, thus signifying a failed test; control vial media
- If test fails, immediately retest to determine if sterilizer is not functioning properly or it was human error (most common reason for test failure)
- If second test fails, remove sterilizer from service immediately and contact your local equipment service provider